Skip Navigation Links My Account | Help
HyperLink
Skip Navigation Links.

Desktop Monitor Troubleshooting

The Desktop Monoitor/Flat Panel Monitor may have the following common symptoms:
Symptom: No picture on screen but power indicate light stays on green.
Solutions: The problem is cause by defective inverter. 
Symptom: Screen flash on and off between 1/2 to a few seconds, but power indicate light stays on green.
Solutions: The problem is cause by defective inverter. 
Symptom: Dark display but still readable.
Solutions: The problem is cause by defective CCFL backlight lamps.
Symptom: Picture stays on in red or pink and slowly be come normal.
Solutions: The problem is cause by defective CCFL backlight lamps.
Symptom: Picture cycles on and off as well as power LED light.
Solutions: The problem is cause by defective power supply.
Symptom: Power light stays on amber but no display.
Solutions: The problem is cause by defective Main Board(AD Board).
Symptom: No Power or Power indicate light does not lits
Solutions: The problem could cause either by defective Power supply board or defective Main Board(AD Board).